ASTM D6513计算标准耐火试验用木框架墙超强荷载的标准规范
日期:2012-02-08 10:05
practicable the maximum load allowed by design under nationally recognized structural design criteria. For this practice, the nationally recognized structural design criteria is the National Design Specification for Wood Construction (NDS).
Alternatively, the standard fire resistance test methods shall be conducted by applying an axial load that is less than the maximum allowable axial load as addressed by the NDS and this practice, but these tests shall be identified in the test report as being