ASTM E936使用钢盖板,预成形屋面绝缘材料和沥青组合屋面屋面系统组件

放大字体  缩小字体 发布日期:2012-02-08   浏览次数:64  分享到: 分享到腾讯微博
ASTM E936使用钢盖板,预成形屋面绝缘材料和沥青组合屋面屋面系统组件
ASTM E936 Standard Practice for Roof System Assemblies Employing Steel Deck, Preformed Roof Insulation, and Bituminous Built-Up Roofing
ASTM E936使用钢盖板,预成形屋面绝缘材料和沥青组合屋面屋面系统组件
This practice covers the performance requirements for the design, components, construction, and service expectations of new roof system assemblies that always include steel deck, preformed roof insulation, and bituminous built-up roofing, and their attachment. It may also include fire-resistive components, integral acoustical treatment, vapor retarder, adhesive or mechanical fastener attachment, and aggregates.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 This practice covers the performance requirements for the design, components, construction, and service expectations of new roof system assemblies. For this purpose, the roof system always includes steel deck, preformed roof insulation, and bituminous built-up roofing, and their attachment. It may also include fire-resistive components, integral acoustical treatment, vapor retarder, adhesive or mechanical fastener attachment, and aggregates.
1.2 The objective is to provide realistic criteria for the overall performance of the roof assembly and its components because by necessity and custom, a roof assembly contains a variety of components and is subject to varied environmental conditions.
1.3 To assist in the successful implementation of the installation and service requirements of the roof system assembly, criteria are established to provide for compatibility of the various components.
1.4 Nothing in this practice is intended to exclude products or systems not covered by the documents referenced in Section 2.
1.5 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
A446/A446M Specification for Steel Sheet, Zinc-Coated (Galvanized) by the Hot-Dip Process, Structural (Physical) Quality
A529/A529M Specification for High-Strength Carbon-Manganese Steel of Structural Quality
A570/A570M Specification for Structural Steel, Sheet and Strip, Carbon, Hot-Rolled
A606 Specification for Steel, Sheet and Strip, High-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, with Improved Atmospheric Corrosion Resistance
A607 Specification for Steel, Sheet and Strip, High-Strength, Low-Alloy Columbium or Vanadium, or Both, Hot-Rolled and Cold-Rolled
A611 Specification for Structural Steel, Sheet, Carbon, Cold-Rolled
A653/A653M Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
B117 Practice for Operating Salt Spray (Fog) Apparatus
C177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus
C208 Specification for Cellulosic Fiber Insulating Board
C209 Test Methods for Cellulosic Fiber Insulating Board
C236 Test Method for Steady-State Thermal Performance of Building Assemblies by Means of a Guarded Hot Box
C518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
C550 Test Method for Measuring Trueness and Squareness of Rigid Block and Board Thermal Insulation
C552 Specification for Cellular Glass Thermal Insulation
C578 Specification for Rigid, Cellular Polystyrene Thermal Insulation
C726 Specification for Mineral Fiber Roof Insulation Board
C728 Specification for Perlite Thermal Insulation Board
C755 Practice for Selection of Water Vapor Retarders for Thermal Insulation
C1013 Specification for Faced Rigid Cellular Polyisocyanurate Roof Insulation
C1126 Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation
C1289 Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board
D41 Specification for Asphalt Primer Used in Roofing, Dampproofing, and Waterproofing
D146 Test Methods for Sampling and Testing Bitumen-Saturated Felts and Woven Fabrics for Roofing and Waterproofing
D226 Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing
D227 Specification for Coal-Tar-Saturated Organic Felt Used in Roofing and Waterproofing
D244 Test Methods and Practices for Emulsified Asphalts
D249 Specification for Asphalt Roll Roofing (Organic Felt) Surfaced with Mineral Granules
D312 Specification for Asphalt Used in Roofing
D371 Specification for Asphalt Roll Roofing (Organic Felt) Surfaced with Mineral Granules; Wide Selvage
D450 Specification for Coal-Tar Pitch Used in Roofing, Dampproofing, and Waterproofing
D1079 Terminology Relating to Roofing and Waterproofing
D1227 Specification for Emulsified Asphalt Used as a Protective Coating for Roofing
D1310 Test Method for Flash Point and Fire Point of Liquids by Tag Open-Cup Apparatus
D1863 Specification for Mineral Aggregate Used on Built-Up Roofs
D2178 Specification for Asphalt Glass Felt Used in Roofing and Waterproofing
D2626 Specification for Asphalt-Saturated and Coated Organic Felt Base Sheet Used in Roofing
D2822 Specification for Asphalt Roof Cement, Asbestos-Containing
D2823 Specification for Asphalt Roof Coatings, Asbestos-Containing
D2824 Specification for Aluminum-Pigmented Asphalt Roof Coatings, Nonfibered, Asbestos Fibered, and Fibered without Asbestos
D2829 Practice for Sampling and Analysis of Existing Built-Up Roof Systems
D3617 Practice for Sampling and Analysis of Built-Up Roof Systems During Application
D3909 Specification for Asphalt Roll Roofing (Glass Felt) Surfaced With Mineral Granules
D4077 Specification for Cumene (Isopropylbenzene)
D4479 Specification for Asphalt Roof Coatings--Asbestos-Free
D4586 Specification for Asphalt Roof Cement, Asbestos-Free
D4601 Specification for Asphalt-Coated Glass Fiber Base Sheet Used in Roofing
D4897 Specification for Asphalt-Coated Glass-Fiber Venting Base Sheet Used in Roofing
D4990 Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing
E84 Test Method for Surface Burning Characteristics of Building Materials
E96/E96M Test Methods for Water Vapor Transmission of Materials
E108 Test Methods for Fire Tests of Roof Coverings
E119 Test Methods for Fire Tests of Building Construction and Materials
E196 Practice for Gravity Load Testing of Floors and Low Slope Roofs
E241 Guide for Limiting Water-Induced Damage to Buildings
E541 Specification for Agencies Engaged in System Analysis and Compliance Assurance for Manufactured Building
E631 Terminology of Building Constructions
E651/E651M Practice for Evaluating Capabilities of Agencies Involved in System Analysis and Compliance Assurance for Manufactured Building
E699 Practice for Evaluation of Agencies Involved in Testing, Quality Assurance, and Evaluating of Building Components
E907 Test Method for Field Testing Uplift Resistance of Adhered Membrane Roofing Systems
Sheet Metal and Air Conditioning Contractors National Association Standard
ArchitecturalSheetMe
The Aluminum Association Incorporated Standard
SpecificationforAlum
Copper Development Association, Inc. Documents
BuildingExpansionJoi
American Welding Society (AWS) Standard
AWSD1.3-81, Specification for Welding Sheet Steel in Structures
National Institute of Standards and Technology Publications
TechnicalNote473&mda Field Comparisons of Built-up Roofing Membranes
Midwest Roofing Contractors Association Document
TenYearsofRoofingRes
Factory Mutual Research Corporation (FM) Documents
FM-1-52 Loss Prevention Data Wind Uplift
Underwriters Laboratories, Inc. (UL) Documents
FireResistanceDirect
National Roofing Contractors Association (NRCA) Document
InServiceR-Values(IS
Steel Deck Institute (SDI) Document
SteelDeckInstituteDe
American Iron and Steel Institute (AISI) Standards
SpecificationfortheD 1986 Edition
American Institute of Architects (AIA)
RoofSystemDesignManu
Canadian Roofing Contractors Association (CRCA)
RoofingManual
American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)
RoofingInsulationRec
Index Terms
bituminous; mechanical attachment; roof insulation; roofing membranes; steel deck;


  详情请咨询
  防火资源网-阻燃防火测试中心
  电话:(+86)0592-5056213
  传真:(+86)0592-5105807
  邮件:firetest@firetc.com

凡注明"防火资源网"的所有作品,由<防火资源网>整理编辑,任何组织未经<防火资源网>及其拥有者授权,不得复制、转载、摘编或利用其它方式应用于任何商业行为。

 
 
[ 防火测试中心搜索 ]  [ ]  [ 告诉好友 ]  [ 打印本文 ]  [ 关闭窗口 ]  [ 返回顶部 ]

 

 
 
推荐防火测试
推荐图文
点击排行
 
 
网站首页 | 广告服务 | 关于我们 | 联系方式 | 服务协议 | 版权声明 | 网站地图 | 友情链接 | 网站留言 | 旧版本 | 闽ICP备09009213号
©2019-2021 FIRETC.COM All Rights Reserved   备案号:闽ICP备09009213号-1在线客服 点击QQ交谈/留言 点击QQ交谈/留言