ASTM F1891雨衣耐电弧和耐火标准规范

放大字体  缩小字体 发布日期:2012-02-08   浏览次数:366  分享到: 分享到腾讯微博
ASTM F1891雨衣耐电弧和耐火标准规范
ASTM F1891 Standard Specification for Arc and Flame Resistant Rainwear
ASTM F1891雨衣耐电弧和耐火标准规范

This specification establishes applicable test methods, minimum physical and thermal performance criteria, a suggested sizing guide, and suggested purchasing information for rainwear for use by workers who may be exposed to thermal hazards of momentary electric arcs and open flames. It does not however apply to electrical contact hazards or electric shock hazards involved with electric arcs nor to flash fire hazards such as industrial hydrocarbon flash fires or other petrochemical flash fire hazards. The rainwear shall be manufactured of materials and constructed using seams that meet the requirements for leak resistance and shall meet the physical requirements of this specification initially as manufactured and after five cleanings. The specimen shall be subjected to tests to determine conformance to the following requirements: flame resistance, tear strength resistance, waterproofness, electric arc resistance, material average weight, arc rating, arc thermal performance value, breakopen threshold energy, heat attenuation factor, and melting and dripping. The material response characteristics for rainwear material, including afterflame time, breakopen, charring, dripping, electric arc ignition, embrittlement, melting, and shrinkage, shall be reported for two typical exposures at least equal to the arc rating and also for two typical exposures at least two times the arc rating.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 This specification establishes applicable test methods, minimum physical and thermal performance criteria, a suggested sizing guide, and suggested purchasing information for rainwear for use by workers who may be exposed to thermal hazards of momentary electric arcs and open flames.
1.1.1 This specification does not apply to the electrical contact hazards or electric shock hazards involved with electric arcs.
1.1.2 This specification does not apply to flash fire hazards such as industrial hydrocarbon flash fires or other petrochemical flash fire hazards.
1.2 The objective of this specification is to prescribe fit, function and performance criteria for rainwear that meets a minimum level of thermal and physical performance when exposed to a laboratory-simulated electric arc or flame exposure.
1.3 This specification is not intended to serve as a detailed manufacturing or purchasing specification, but can be referenced in purchase contracts to ensure that minimum performance requirements are met.
1.4 Controlled laboratory tests used to determine compliance with the performance requirements of this specification shall not be deemed as establishing performance levels for all situations to which wearers of this protective clothing may be exposed.
1.5 The in-service care and use of this rainwear is beyond the scope of this specification.
1.6 The values stated in inch-pound units are to be regarded as the standard. The SI units shown in parentheses are for information only.
The following safety hazards caveat pertains only to Sections and , of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
D123 Terminology Relating to Textiles
D751 Test Methods for Coated Fabrics
D1117 Guide for Evaluating Nonwoven Fabrics
D1388 Test Method for Stiffness of Fabrics
D3393 Specification for Coated Fabrics--Waterproofness
D3776 Test Methods for Mass Per Unit Area (Weight) of Fabric
D4391 Terminology Relating to The Burning Behavior of Textiles
D6413 Test Method for Flame Resistance of Textiles (Vertical Test)
F1494 Terminology Relating to Protective Clothing
F1958/F1958M Test Method for Determining the Ignitability of Non-flame-Resistant Materials for Clothing by Electric Arc Exposure Method Using Mannequins
F1959/F1959M Test Method for Determining the Arc Rating of Materials for Clothing
Federal Specifications
FederalTestMethodSta Method 5204
AATCC Standards
AATCCTestMethod135 Dimensional Changes Automatic Home Laundering of Woven and Knitted Fabrics
Index Terms
arc thermal performance value; breakopen threshold energy; electric arc; electric arc ignition; flame resistant; heat attenuation factor; incident energy; leak resistant; thermal hazard;
 

  详情请咨询
  防火资源网-阻燃防火测试中心
  电话:(+86)0592-5056213
  传真:(+86)0592-5105807
  邮件:firetest@firetc.com

凡注明"防火资源网"的所有作品,由<防火资源网>整理编辑,任何组织未经<防火资源网>及其拥有者授权,不得复制、转载、摘编或利用其它方式应用于任何商业行为。

 
 
[ 防火测试中心搜索 ]  [ ]  [ 告诉好友 ]  [ 打印本文 ]  [ 关闭窗口 ]  [ 返回顶部 ]

 

 
 
推荐防火测试
推荐图文
点击排行
 
 
网站首页 | 广告服务 | 关于我们 | 联系方式 | 服务协议 | 版权声明 | 网站地图 | 友情链接 | 网站留言 | 旧版本 | 闽ICP备09009213号
©2019-2021 FIRETC.COM All Rights Reserved   备案号:闽ICP备09009213号-1在线客服 点击QQ交谈/留言 点击QQ交谈/留言